Institutional Repository in Medical Sciences
(IRMS – Nicolae Testemițanu SUMPh)

Particularități individuale ale indicilor morfometrici ai arterei axilare

Show simple item record

dc.contributor.author Zorina, Zinovia
dc.contributor.author Babuci, Angela
dc.contributor.author Catereniuc, Ilia
dc.contributor.author Bendelic, Anastasia
dc.contributor.author Stratulat, Silvia
dc.contributor.author Ostahi, Nadia
dc.contributor.author Botnari, Tatiana
dc.contributor.author Botnaru, Doina
dc.date.accessioned 2025-10-23T15:51:27Z
dc.date.available 2025-10-23T15:51:27Z
dc.date.issued 2025
dc.identifier.citation ZORINA, Zinovia, Angela BABUCI; Ilia CATERENIUC; Anastasia BENDELIC; Silvia STRATULAT; Nadia OSTAHI; Tatiana BOTNARI și Doina BOTNARU. Particularități individuale ale indicilor morfometrici ai arterei axilare. In: Probleme actuale ale morfologiei. Materialele Conferinței științifice internaționale dedicată aniversării a 80 de ani de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova. Chișinău, 17-18 octombrie, 2025 (sub red. Ilia Catereniuc). Chișinău, 2025, pp. 286-290. en_US
dc.identifier.uri https://repository.usmf.md/handle/20.500.12710/31279
dc.description.abstract Background Lately, the radial artery has been increasingly used in coronary angiography and in cases when its diameter is too small, or there occurs a spasm after the introduction of the contrast medium, the axillary artery is used. In order to avoid injury to the brachial plexus during catheterization of the axillary artery, it is necessary to know both the anatomo-topographic peculiarities and its morphometric parameters. The aim of the study was to evaluate the morphometric parameters of the axillary artery and of its branches depending on gender and constitutional type. Material and methods The upper limb arteries were studied on 210 angiographies of both genders, taken from the database of the Euromed Diagnostic Medical Center, Chisinau, Republic of Moldova. By determining the proportionality index of the humerus thickness/length, three constitutional types were established. Using the RadiAnt DICOM Viewer 3.42 software, the length of the axillary artery, its proximal/distal internal diameter, as well as the proximal internal diameter of all its branches were determined. Results The mean length of the axillary artery was 8.69±0.15 cm; in males – 8.98±0.18 cm, in females – 8.25±0.25 cm. The proximal internal diameter of the axillary artery was 7.82±0.16 mm, and the distal one – 6.38±0.14 mm; depending on gender, its proximal diameter was 8.08±0.20 mm in males and 7.40±0.24 mm in females, and the distal one – 6.6±0.19 mm in males and 6.03±0.20 mm in females. Conclusions Advanced imaging methods have the capacity for precise description of the individual peculiarities of the axillary artery morphometric parameters. en_US
dc.language.iso ro en_US
dc.publisher Instituţia Publică Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu” din Republica Moldova en_US
dc.relation.ispartof Probleme actuale ale morfologiei. Conferință științifică internațională dedicată aniversării a 80 de ani de la fondarea Universității de Stat de Medicină și Farmacie „Nicolae Testemițanu” din Republica Moldova. Chișinău, 17-18 octombrie, 2025 en_US
dc.subject axillary artery en_US
dc.subject morphometric parameters en_US
dc.subject constitutional type en_US
dc.title Particularități individuale ale indicilor morfometrici ai arterei axilare en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics