Abstract:
Introduction
Radon is a naturally occurring radioactive gas and the main
source of ionizing radiation exposure for the general
population. The principal indoor source is soil and
underlying geology beneath buildings; additional contributors include groundwater and certain construction materials
such as concrete, bricks, natural stone, gypsum, slag, and fly
ash. Variability in sources and transport mechanisms
influences the effectiveness of prevention and mitigation
measures.
Aim of the study
To systematize practical strategies for radon prevention and
mitigation in residential buildings, with emphasis on
reducing public health risks.
Material and methods
Regulatory provisions, technical guidance, and measurement protocols concerning radon control were examined.
Approaches for assessing radon potential, testing buildings,
applying radon-resistant construction techniques, and
implementing mitigation measures in existing dwellings
were analyzed in relation to building characteristics, climatic
conditions, and reference levels. Results
Effective radon control requires both preventive measures in
new buildings and remediation in existing ones. Radon
potential can be assessed through regional mapping or sitespecific investigations before construction, allowing the
determination of appropriate protection levels. Testing of
new buildings is recommended before occupancy, when
corrective actions are easier to implement, and after
occupancy to confirm compliance with reference levels and
long-term system performance. Preventive techniques
include passive or active soil depressurization, sealing of
surfaces and joints, installation of radon barriers and
membranes, ventilation systems, drainage systems, and
water treatment when necessary. Radon-resistant
construction typically incorporates a gas-permeable layer,
anti-radon membrane, sealing elements, vent pipe, and
ventilation systems. In existing buildings, mitigation focuses
on active soil depressurization, improved ventilation, sealing
of cracks and openings, and treatment of radon in water.
Measures must be selected based on standardized radon
measurements and adapted to specific building features and
radon entry pathways. Older or poorly insulated houses are
generally more vulnerable. According to WHO and national
recommendations, action is strongly advised when indoor
radon exceeds 300 Bq/m³. For levels between 100-300
Bq/m³, improved ventilation and behavioral changes are
recommended, while concentrations above 300 Bq/m³
require structural remediation.
Conclusion
Integration of radon potential assessment, radon-resistant
construction, systematic testing, and targeted mitigation is
essential for sustainable reduction of radon exposure and